Parameter Program - NEPC 225Kw - Wind Mills

 

 

 Parameter Program - NEPC 225Kw - Wind Mills or Wind Turbines

 


Parameter Program

        Parameters are the values and set points in wind turbines or wind mill each and every line of parameters also important. every single line parameter has a meaning , one line parameter enough to change the machine's status so you need to check and set every parameters carefully .

   This program is special and important one. Because, all parameters are set using this particular program. For example maximum wind speed, minimum wind speed, maximum rotor rpm, maximum generator rpm, maximum power, cut-in and cut-out time, etc,..

password : 55547890

Code :

Explanation:

  • Date and time is used to set the current date and time.
  • BAUD rate is used to serial communications.
  • phone numbers are used to get a emergency alarm when machine fault raise.
  • id number mention the wind turbines identity number.
  • The three CAL LINE V is used to calibrate the voltage of three phases of RYB.
  • The three CAL LINE I is used to calibrate the Ampere of three phases of RYB.
  • max cut is maximum limit time to machine cut in.
  • breaking time is set the maximum time take to break machine .
  • hub motor is set time how much time hub motor want to run.
  • stop wind is set the maximum wind speed want to machine run.
  • temp 1-10 is used to set the set point and alarm of temperature variations.
  • g pulse is generator rpm reading per pulse
  • max volt is set the maximum voltage .
  • min volt is used to set the minimum voltage.
  • nominal frequency is use to set the value of nominal frequency value.
  • maximum frequency is use to set the value of maximum frequency value.
  • minimum frequency is use to set the value of minimum frequency value.
  • compensation parameters are used to set the compensation values in steps and set time to when steps turned on.
  • max rotor is used to set the maximum value of rotor rpm.
  • max gen is used to set the maximum value of generator rpm.
  • max power is used to set the maximum value of kilo watts reads. 
  • I1-I2-I3 is mention the ampere variation in three phases and how much time variation occur to raise fault
  • Yaw count is the reading of yaw counts.
  • wait yawing is used to how much time wait for yawing after wind vane signal coming continuously.
  • 1-32 invert points is the controllers input section that have all sensors signals read it have been set based on your your system and signal come or not.
  • free wheeling is the without generating electricity machine running while low wind time.
  • start wind is the set point to machine being reset after the minimum wind speed occur.
  • 1 gen operation mode is enable the machine runs with single generation mode
  •  after that all are used to set when machine going to cut in, release, G1, G2, pause based on wind speed, ampere, and kilo watts.

 

 